Introduction
The State Chart subsystem provides the commands necessary for
programming the HP 16554A/HP 16555A/HP 16555D's Chart display.
The commands allow you to build charts of label activity, using data
normally found in the Listing display. The chart's Y axis is used to
show data values for the label of your choice. The X axis can be used
in two different ways. In one, the X axis represents states (shown as
rows in the State Listing display). In the other, the X axis represents
the data values for another label.
When states are plotted along the X axis, X and O markers are
available. Because the State Chart display is simply an alternative way
of looking at the data in the State Listing, the X and O markers are
manipulated through the SLISt subsystem. Because the programming
commands do not force the menus to switch, you can position the
markers in the SLISt subsystem and see the effects in the State Chart
display.
The commands in the SCHart subsystem are: