HP 16554A Programmer's Manual page 34

State/timing logic analyzers
Table of Contents

Advertisement

Programming the HP 16554A/ HP 16555A/HP 16555D
MESR<N>
Table 1-3
Module Event Status Register
Bit
7
6
5
4
3
2
1
0
1–16
Weight
Condition
128
Not used
64
Not used
32
Not used
16
Not used
8
1 = One or more pattern searches failed
0 = Pattern searches did not fail
4
1 = Trigger found
0 = Trigger not found
2
1 = Run until satisfied
0 = Run until not satisfied
1
1 = Measurement complete
0 = Measurement not complete