Press [Esc] key to return to the previous menu level.
The descriptions of configuration menu are listed in the table below.
Config
Configuration menu of the power supply
Mode
V-Rise Time/I-Rise Time
= 0.001s
V-Fall Time/I-Fall Time =
0.001s
Output Res
On Delay
Off Delay
Copyright © Itech Electronic Co., Ltd.
CC/CV priority mode setting
Constant voltage loop priority mode
CV
Speed= High/Low
Constant current loop priority mode
CC
Speed= High/Low
Displays the voltage or current rise time
setting according to the selected priority
mode. If CC priority mode is selected,
the parameter setting of I-Rise Time will
be displayed here.
Displays the voltage or current fall time
setting according to the selected priority
mode. If CC priority mode is selected,
the parameter setting of I-Fall Time will
be displayed here.
Set the internal resistance of the power
supply. This parameter needs to be set
only when Mode is set to CV.
Set the delay time to turn on the output.
Set the delay time to turn off the output.
www.tehencom.com
Power Supply Function
Loop response
speed setting:
high speed /
low speed
Loop response
speed setting:
high speed /
low speed
66