4.6.3.5 LV124
The built-in curves LV124 can meet general requirements, test conditions and
tests of electrical and electronic components in motor vehicles up to 3.5 t. Re-
lated parameters are as below:
LV124
LV124 waveform protocol
E-02
E-04
E-05
E-07
E-08
E-09
E-11
E-12
Copyright © Itech Electronic Co., Ltd.
Transient overvoltage test waveform
Jump start test waveform
Load dump test waveform
Slow decrease and increase of the supply
voltage test waveform
Ubmax
Start voltage
Ubmin
Holding voltage
Ubmin
Voltage holding time at
Holding
Ubmin
Time
Slow decrease, quick increase of the sup-
ply voltage test waveform
Ubmax
Start voltage
Ubmin
Holding voltage
Ubmin
Voltage holding time at
Holding
Ubmin
Time
Reset behavior test waveform
Ubmin
Holding voltage
Start pulses
Cold-Start
Cold start
Normal
Server
Warm-Start
Warm start
Voltage curve with intelligent generator
control