How to Use
Taking the triggering of List function as an example, the text below will introduce
how to use pin 4's default function Ext-Trig.
•
Trig–Out
1. Refer to the figure below to connect pin 4 to the external oscilloscope.
Copyright © Itech Electronic Co., Ltd.
Dlog
List
Input
Pin 4 receives the level signal from the
outside.
Output
Pin 4 sends the digital signal (1, 0, PWM)
to the outside.
True
By default (Not-Invert), the out-
put digital signal is 1 (i.e. low
level), and in the case of Invert,
the output is high level.
False
By default (Not-Invert), the out-
put digital signal is 0 (i.e. high
level), and in the case of Invert,
the output is low level.
PWM
Digital signal of PWM.
PWM Freq
PWM Duty
www.tehencom.com
Basic Operation
instructions re-
lated to ACQuire
in the Trigger
subsystem of the
Instruction
Manual.
Triggers the run-
ning of data re-
cording function.
Triggers the run-
ning of List files.
Frequency
Duty cycle
47