Leica TPS1200 Series Reference Manual page 82

Geodetic measurement instruments
Hide thumbs Also See for TPS1200 Series:
Table of Contents

Advertisement

GeoCOM Reference Manual
8.3.12
BAP_MeasDistanceAngle – measuring Hz,V angles and a single distance
BAP_MeasDistanceAngle .............................................................................................................................................................................................................................................................................
.................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................... 17017
17017...............................................................................................................................................................................................................................................................BAP_MeasDista
nceAngle
C-Declaration
BAP_MeasDistanceAngle(BAP_MEASURE_PRG &DistMode,
VB-Declaration
VB_BAP_MeasDistAng(DistMode As Long,
ASCII-Request
%R1Q,17017:DistMode[long]
ASCII-Response
%R1P,0,0:RC, dHz[double], dV[double], dDist[double],DistMode[long]
Remarks
This function measures angles and a single distance depending on the mode
not suited for continuous measurements (LOCK mode and TRK mode). This command uses the current
automation settings.
Parameters
DistMode
DistMode
dHz
dV
dDist
Return-Code Names and Return-Code Values
BAP_MeasDistanceAngle
GRC_OK
GRC_AUT_ANGLE_ERROR
GRC_AUT_BAD_ENVIRONMENT
GRC_AUT_CALACC
GRC_AUT_DETECTOR_ERROR
GRC_AUT_DEV_ERROR
GRC_AUT_INCACC
GRC_AUT_MOTOR_ERROR
GRC_AUT_MULTIPLE_TARGETS
GRC_AUT_NO_TARGET
GRC_AUT_TIMEOUT
TMC_ACCURACY_GUARANTEE
TMC_ANGLE_ACCURACY_
GUARANTEE
TMC_ANGLE_ERROR
TMC_ANGLE_NO_FULL_
CORRECTION
TMC_ANGLE_OK
TMC_BUSY
TMC_DIST_ERROR
TMC_DIST_PPM
TMC_NO_FULL_CORRECTION
TMC_SIGNAL_ERROR
Leica TPS1200 / TS30 / TM30 – Version 1.50
double &dHz, double &dV,
double &dDist)
dHz As Double, dV As Double
dDist As Double)
In
Out
Out
Out
Out
may additionally return AUT- and TMC-return codes.
0
8706
8712
8715
8713
8709
8708
8707
8711
8710
8704
1284
1289
1290
1288
1285
1293
1292
1291
1283
1294
uses the predefined distance measurement
BAP_DEF_DIST
program as defined in
BAP_SetMeasPrg
Actual distance measurement mode
Horizontal angle [rad]x, depends on
Vertical angle [rad]x, depends on
Slopedistance [m]x, depends on
Execution successful.
Angle measurement error
Bad Environment conditions
ATR-calibration failed
Error in target acquisition
Deviation measurement error
Position not exactly reached
Motorization error
Multiple targets detected
No target detected
Position not reached
Info, accuracy cannot be guaranteed
Info, only angle measurement valid, accuracy cannot be
guaranteed
Error, no valid angle measurement
Warning, only angle measurement valid, accuracy cannot be
guaranteed
Warning, only angle measurement valid
Error, TMC submodule already in use by another subsystem,
command not processed
An error occurred during distance measurement.
Error, wrong setting of PPM
Warning, measurement without full correction
Error, no signal on EDM (only in signal mode)
Basic Applications – BAP
. Note that this function is
DistMode
DistMode
DistMode
DistMode
82

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tm30Ts30Tps1200+

Table of Contents