17.6.12
TMC_SetStation - setting the station coordinates of the instrument
TMC_SetStation............................................................................................................................................................................................................................................................................. .................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................... 2010
2010 ................................................................................................................................................................................................................................................................TMC_SetStation
C-Declaration
TMC_SetStation(TMC_STATION Station)
VB-Declaration
VB_TMC_SetStation(ByVal Station As TMC_STATION)
ASCII-Request
%R1Q,2010:E0[double],N0[double],H0[double],Hi[double]
ASCII-Response
%R1P,0,0:RC
Remarks
This function is used to set the station coordinates of the instrument.
Parameters
Station
Return-Code Names and Return-Code Values
GRC_OK
GRC_TMC_BUSY
See Also
TMC_GetStation
TMC_DoMeasure
Example
see
TMC_GetStation
Leica TPS1200 – Version 1.50
Theodolite Measurement and Calculation – TMC
In
Instrument station co-ordinates [m].
0
Execution successful.
1293
TMC resource is locked respectively TMC task is busy or a
distance is existing. The instrument co-ordinates are not set.
Clear distance and repeat measurement.