Communications - Com; Usage; Constants And Types - Leica TPS1200 Series Reference Manual

Geodetic measurement instruments
Hide thumbs Also See for TPS1200 Series:
Table of Contents

Advertisement

GeoCOM Reference Manual
10 C
OMMUNICATIONS

10.1 USAGE

This subsystem contains those functions, which are subsystem COM related, but will be executed as RPC's on the
TPS1200 instrument. It provides a function to check communication between the computer and the TPS1200 and also
some functions to get and set communication relevant parameters on the server side. Furthermore, it implements
functions to switch on or off (sleep mode, shut down) the TPS1200 instrument.

10.2 CONSTANTS AND TYPES

Stop Mode
enum COM_TPS_STOP_MODE
{
COM_TPS_STOP_SHUT_DOWN =0, // power down instrument
COM_TPS_STOP_SLEEP
};
Start Mode
enum COM_TPS_STARTUP_MODE
{
COM_TPS_STARTUP_LOCAL =0 // not supported by TPS1200
COM_TPS_STARTUP_REMOTE=1 // RPC's enabled, online mode
};
Leica TPS1200 – Version 1.50
– COM
=1
// not supported by TPS1200
Communications – COM