GeoCOM Reference Manual
GRC_ANG_BAD_INCLIN_ACC
GRC_ANG_WRITE_PROTECTED
GRC_ANG_OUT_OF_RANGE
GRC_ANG_IR_OCCURED
GRC_ANG_HZ_MOVED
GRC_ANG_OS_ERROR
GRC_ANG_DATA_ERROR
GRC_ANG_PEAK_CNT_UFL
GRC_ANG_TIME_OUT
GRC_ANG_TOO_MANY_EXPOS
GRC_ANG_PIX_CTRL_ERR
GRC_ANG_MAX_POS_SKIP
GRC_ANG_MAX_NEG_SKIP
GRC_ANG_EXP_LIMIT
GRC_ANG_UNDER_EXPOSURE
GRC_ANG_OVER_EXPOSURE
GRC_ANG_TMANY_PEAKS
GRC_ANG_TLESS_PEAKS
GRC_ANG_PEAK_TOO_SLIM
GRC_ANG_PEAK_TOO_WIDE
GRC_ANG_BAD_PEAKDIFF
GRC_ANG_UNDER_EXP_PICT
GRC_ANG_PEAKS_INHOMOGEN
GRC_ANG_NO_DECOD_POSS
GRC_ANG_UNSTABLE_DECOD
GRC_ANG_TLESS_FPEAKS
GRC_ANG_INCL_OLD_PLANE
GRC_ANG_INCL_NO_PLANE
GRC_ANG_FAST_ANG_ERR
GRC_ANG_FAST_ANG_ERR_5
GRC_ANG_FAST_ANG_ERR_25
GRC_ANG_TRANS_ERR
GRC_ANG_TRANS_ERR_5
GRC_ANG_TRANS_ERR_25
ATA
RetCodeName
GRC_ATA_NOT_READY
GRC_ATA_NO_RESULT
GRC_ATA_SEVERAL_TARGETS
GRC_ATA_BIG_SPOT
GRC_ATA_BACKGROUND
GRC_ATA_NO_TARGETS
GRC_ATA_NOT_ACCURAT
GRC_ATA_SPOT_ON_EDGE
GRC_ATA_BLOOMING
GRC_ATA_NOT_BUSY
GRC_ATA_STRANGE_LIGHT
GRC_ATA_V24_FAIL
GRC_ATA_DECODE_ERROR
GRC_ATA_HZ_FAIL
GRC_ATA_V_FAIL
Leica TPS1200 – Version 1.50
261
0x105
266
0x10A
267
0x10B
268
0x10C
269
0x10D
270
0x10E
271
0x10F
272
0x110
273
0x111
274
0x112
275
0x113
276
0x114
277
0x115
278
0x116
279
0x117
280
0x118
300
0x12C
301
0x12D
302
0x12E
303
0x12F
304
0x130
305
0x131
306
0x132
307
0x133
308
0x134
309
0x135
316
0x13C
317
0x13D
326
0x146
327
0x147
328
0x148
329
0x149
330
0x14A
331
0x14B
512
0x200
Value
HexVal
512
0x200
513
0x201
514
0x202
515
0x203
516
0x204
517
0x205
518
0x206
519
0x207
522
0x20A
523
0x20B
524
0x20C
525
0x20D
526
0x20E
527
0x20F
528
0x210
Return-Code names and return-code values
inclination accuracies not reached
no write access allowed
value out of range
function aborted due to interrupt
hz moved during incline measurement
troubles with operation system
overflow at parameter values
too less peaks
reading timeout
too many exposures wanted
picture height out of range
positive exposure dynamic overflow
negative exposure dynamic overflow
exposure time overflow
picture underexposured
picture overexposured
too many peaks detected
too less peaks detected
peak too slim
peak to wide
bad peak difference
too less peak amplitude
inhomogeneous peak amplitudes
no peak decoding possible
peak decoding not stable
too less valid finepeaks
inclination plane out of time range
inclination no plane available
errors in 5kHz and or 2.5kHz angle
errors in 5kHz angle
errors in 2.5kHz angle
LVDS transfer error detected
LVDS transfer error detected in 5kHz mode
LVDS transfer error detected in 2.5kHz mode
Description
ATR-System is not ready.
Result isn't available yet.
Several Targets detected.
Spot is too big for analyse.
Background is too bright.
No targets detected.
Accuracy worse than asked for.
Spot is on the edge of the sensing area.
Blooming or spot on edge detected.
ATR isn't in a continuous mode.
Not the spot of the own target illuminator.
Communication error to sensor (ATR).
Received Arguments cannot be decoded
No Spot detected in Hz-direction.
No Spot detected in V-direction.