GeoCOM Reference Manual
17.6.16
TMC_SetGeoPpm – setting the geometric ppm correction factor
TMC_GetSlopeDistCorr............................................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................ 2126
2126 ................................................................................................................................................................................................................................................................TMC_GetSlopeD
istCorr
C-Declaration
TMC_SetGeoPpm(unsigned short unGeomUseAutomatic,
VB-Declaration
VB_TMC_SetGeoPpm(ByVal unGeomUseAutomatic as Integer,
ASCII-Request
%R1Q,2153:unGeomUseAutomatic[unsigned short],dScaleFactorCentralMeridian[double],
dOffsetCentralMeridian[double],dHeightReductionPPM[double],dIndividualPPM[double]
ASCII-Response
%R1P,0,0:RC
Remarks
This function is used to set the geometric ppm values.
Parameters
unGeomUseAutomatic
dScaleFactorCentralMeridian
dOffsetCentralMeridian
dHeightReductionPPM
dIndividualPPM
Return-Code Names and Return-Code Values
GRC_OK
See Also
TMC_GetAtmPpm
TMC_SetAtmPpm
TMC_GetGeoPpm
TMC_GetPrismCorr
TMC_SetPrismCorr
Example
see TMC_SetPrismCorr
Leica TPS1200 – Version 1.50
double dScaleFactorCentralMeridian,
double dOffsetCentralMeridian,
double dHeightReductionPPM,
double dIndividualPPM)
ByVal dScaleFactorCentralMeridian as Double,
ByVal dOffsetCentralMeridian as Double,
ByVal dHeightReductionPPM as Double,
ByVal dIndividualPPM as Double)
In
In
In
In
In
0
Theodolite Measurement and Calculation – TMC
Current state of the Geometric ppm calculation switch
(automatic or manual)
Scale factor on central meridian
Offset from central meridian [m]
ppm value due to height above reference
Individual ppm value
Execution successful.
176