GeoCOM Reference Manual
17.4.5
TMC_QuickDist - returning a slope distance and hz-angle, v-angle
TMC_QuickDist.............................................................................................................................................................................................................................................................................
.................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................... 2117
2117 ................................................................................................................................................................................................................................................................TMC_QuickDis
t
C-Declaration
TMC_QuickDist(
VB-Declaration
VB_TMC_QuickDist(
ASCII- Request
%R1Q,2117:
ASCII-Response
%R1P,0,0:RC,dHz[double],dV[double],dSlopeDistance[double]
Remarks
The function starts an EDM Tracking measurement and waits until a distance is measured. Then it returns the
angle and the slope-distance, but no co-ordinates. If no distance can be measured, it returns the angle values (hz,
v) and the corresponding return-code.
In order to abort the current measuring program use the function
Parameters
OnlyAngle
dSlopeDistance
Return-Code Names and Return-Code Values
GRC_OK
GRC_TMC_ACCURACY_GUARANTEE
GRC_TMC_NO_FULL_CORRECTION
GRC_TMC_ANGLE_OK
GRC_TMC_ANGLE_NO_ACC_
GUARANTY
GRC_TMC_ANGLE_NO_FULL_
CORRECTION
GRC_TMC_DIST_ERROR
GRC_TMC_DIST_PPM
GRC_TMC_ANGLE_ERROR
GRC_TMC_BUSY
GRC_ABORT
GRC_SHUT_DOWN
Leica TPS1200 – Version 1.50
TMC_HZ_V_ANG &OnlyAngle,
double
&dSlopeDistance)
OnlyAngle
TMC_HZ_V_ANG,
dSlopeDistance As Double)
Out
Out
0
1284
1283
1285
1289
1288
1292
1291
1290
1293
8
12
Theodolite Measurement and Calculation – TMC
As
TMC_DoMeasure
measured Hz- and V- angle
measured slope-distance
Execution successful.
Accuracy is not guaranteed, because the result are consist of
measuring data which accuracy could not be verified by the
system. Co-ordinates are available.
The results are not corrected by all active sensors. Co-
ordinates are available.
In order to secure which correction is missing use the both
functions
TMC_IfDataAzeCorrError
TMC_IfDataIncCorrError
Angle values okay, but no valid distance. Co-ordinates are
not available.
Only the angle measurement is valid but its accuracy cannot
be guaranteed (the tilt measurement is not available).
No distance data available but angle data are valid. The return
code is equivalent to the
and relates to the angle data. Co-ordinates are not available.
Perform a distance measurement first before you call this
function.
No measuring, because of missing target point, co-ordinates
are not available.
Aim target point and try it again
No distance measurement respectively no distance data
because of wrong EDM settings. Co-ordinates are not
available.
Angle or inclination measurement error. Check inclination
modes in commands.
TMC resource is locked respectively TMC task is busy.
Repeat measurement.
Measurement through customer aborted.
System power off through customer.
.
and
GRC_TMC_NO_FULL_CORRECTION