GeoCOM Reference Manual
6.3.2 AUS_SetUserAtrState - setting the status of the ATR mode
AUS_SetUserAtrState............................................................................................................................................................................................................................................................................
............................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................ 18005
18005...............................................................................................................................................................................................................................................................AUS_SetUserAt
rState
C-Declaration
AUS_SetUserAtrState(ON_OFF_TYPE OnOff)
VB-Declaration
VB_AUS_SetUserAtrState(OnOff As Long)
ASCII-Request
%R1Q,18005:On/Off[long]
ASCII-Response
%R1P,0,0:RC
Remarks
Activates respectively deactivates the ATR mode.
Activate ATR mode:
The ATR mode gets activated. If LOCK mode is on and the command is sent, then LOCK mode changes to ATR
mode.
Deactivate ATR mode:
The ATR mode gets deactivated. If LOCK mode is on and the command is sent, then LOCK mode stays on
This command is valid for automated instrument models only.
Parameters
OnOff
Return-Code Names and Return-Code Values
GRC_OK
GRC_NOT_IMPL
See Also
AUS_GetUserAtrState
AUS_GetUserLockState
AUS_SetUserLockState
Example
see AUS_GetUserAtrState
Leica TPS1200 / TS30 / TM30 – Version 1.50
in
State of the ATR mode
0
Execution successful.
5
ATR not available; no automated instrument.
Alt User - AUS