17.6.2
TMC_SetHeight – setting a new reflector height
TMC_SetHeight.............................................................................................................................................................................................................................................................................. .................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................... 2012
2012 ................................................................................................................................................................................................................................................................TMC_SetHeight
C-Declaration
TMC_SetHeight(TMC_HEIGHT Height)
VB-Declaration
VB_TMC_SetHeight(ByVal Height As TMC_HEIGHT)
ASCII-Request
%R1Q,2012:Height[double]
ASCII-Response
%R1P,0,0:RC
Remarks
This function sets a new reflector height.
Parameters
Height
Return-Code Names and Return-Code Values
GRC_OK
GRC_TMC_BUSY
GRC_IVPAR
See Also
TMC_GetHeight
Example
see
TMC_GetHeight
Leica TPS1200 – Version 1.50
Theodolite Measurement and Calculation – TMC
In
new reflector height [m]
0
Execution successful.
1293
TMC resource is locked respectively TMC task is busy. The
reflector height is not set.
Repeat measurement.
2
A reflector height less than 10m or greater than 100m is
entered. Invalid parameter.