Table 75. Maximum vibration specifications (continued)
Maximum vibration
Storage
Table 76. Maximum shock pulse specifications
Maximum shock pulse
Operating
Storage
Table 77. Maximum altitude specifications
Maximum altitude
Operating
Storage
Table 78. Operating temperature derating specifications
Operating temperature derating
Up to 35°C (95°F)
35–40°C (95–104°F)
40–45°C (104–113°F)

Standard operating temperature

Table 79. Standard operating temperature specifications
Standard operating temperature
Continuous operation (for altitude less than 950 m or 3117
ft)

Expanded operating temperature

Table 80. Expanded operating temperature specifications
Expanded operating temperature
Continuous operation
≤ 1% of annual operating hours
Specifications
1.88 G
at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
rms
Specifications
24 run shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11
ms. (4 pulse on each side of the system)
Six consecutively run shock pulses in the positive and negative x, y, and z axis
(one pulse on each side of the system) of 71 G for up to 2 ms.
Specifications
3048 m (10,000 ft)
12,000 m (39,370 ft)
Specifications
Maximum temperature is reduced by 1°C/300 m (1°F/547 ft), above 950 m
(3,117 ft).
Maximum temperature is reduced by 1°C/175 m (1°F/319 ft), above 950 m (3,117
ft).
Maximum temperature is reduced by 1°C/125 m (1°F/228 ft), above 950 m
(3,117 ft).
Specifications
10–35°C (50–95°F) with no direct sunlight on the equipment.
Specifications
5°C–40°C at 5% to 85% RH with 29°C dew point.
NOTE:
Outside the standard operating temperature
(10°C–35°C), the system can operate continuously in
temperatures as low as 5°C and as high as 40°C.
For temperatures 35°C– 40°C, derate maximum allowable
temperature by 1°C per 175 m (1°F per 319 ft) above 950 m
(3,1171 ft).
-5°C–45°C at 5% to 90% RH with 29°C dew point.
NOTE:
Outside the standard operating temperature
(10°C–35°C), the system can operate down to -5°C or
Technical specifications