Verifying The Stack - Allied Telesis x530 Series Installation Manual

Stackable gigabit layer 3+ ethernet switches alliedware plus v5.4.8-2
Hide thumbs Also See for x530 Series:
Table of Contents

Advertisement

Chapter 7: Powering On the Stack

Verifying the Stack

awplus> show stack
awplus> show stack
Virtual Chassis Stacking summary information
ID
Pending ID
1
-
2
-
3
-
Operational Status
102
To verify the stack, perform the following procedure:
1. Start a local management session on any switch in the stack. Refer to
"Starting a Local Management Session" on page 100.
2. From the User Exec mode, type the SHOW STACK command:
The following example is from a stack of three switches:
MAC address
e01a:ea20:8011
e01a:ea20:8012
e01a:ea20:8902
Review the following items:
1) The command should list all switches. If the list is incomplete, refer
to Chapter 9, "Troubleshooting" on page 117.
The Operational Status field should be "Normal operations" to
indicate that all of the stacking ports are operating normally.
If the Operational Status field is displaying "Not all stack ports are
up," one or more stacking ports are not being used or cannot
establish links with their counterparts. For more information, refer
to Chapter 9, "Troubleshooting" on page 117.
3. If you want to add ports 25 and 26 to the stack trunk, perform "Adding
Ports 25 and 26 to the Stack Trunk" on page 103. Otherwise, g o to
Chapter 8, "Cabling the Networking Ports" on page 109, to complete
the installation.
Priority
Status
1
Ready
2
Ready
3
Ready
Normal operations
Role
Active Master
Member
Member

Advertisement

Table of Contents
loading

This manual is also suitable for:

At-x530-28gpxmAt-x530-28gtxm

Table of Contents