Ventilation Of The Spray Booth - WAGNER GM 5000EAC F Operating Manual

Electrostatic aircoat spray gun for manual operation and for flat or round jet nozzles
Hide thumbs Also See for GM 5000EAC F:
Table of Contents

Advertisement

EDITION 07/2014
OPERATING MANUAL
The GM 5000EAC spray gun must be used as part of a spraying system (Spraypack). The
system shown in fi gure B_03158 is only one example of an electrostatic spraying system.
Your WAGNER distributor would be happy to assist you in creating a spraying system
solution that meets your individual needs. You must familiarize yourself with the operating
instructions and the safety regulations of all additional system components before starting
commissioning.
Incorrect installation/operation!
Risk of injury and equipment damage.
6.4.2

VENTILATION OF THE SPRAY BOOTH

The electrostatic hand spraying equipment is for use only in spray areas which correspond
with standard EN 12215.
The electrostatic hand spraying equipment has to be locked to the technical ventilation
so that the coating product supply and the high-voltage are not eff ective as long as the
technical ventilation is not operated with the minimum exhaust air volume fl ow or a larger
exhaust air volume fl ow.
Ensure that the excess coating product (overspray) will be collected up safely.
Toxic and/or fl ammable vapor mixtures!
Risk of poisoning and burns.
ORDER NUMBER DOC 2344500
WARNING
When commissioning and for all work, read and follow the
operating manual and safety regulations for the additionally
required system components.
WARNING
Operate the device in a spray booth approved for the working
products.
-or-
Operate the device on an appropriate spraying wall with the
ventilation (extraction) switched on.
Observe national and local regulations for the outgoing air
speed.