CLEANING

De-energize the device electrically.
Disconnect the pneumatic supply line.
Relieve the pressure from the device.
Ensure that the fl ash point of the cleaning agent is at least 15 K above the ambient
temperature or that cleaning is undertaken at a cleaning station with technical ventilation.
To clean, use cloths and brushes moistened with solvent. Abrasive agents or objects
must not be used. Ensure that the spray gun is not damaged in any way while cleaning.
Parts of the spray gun must not be sprayed with or immersed into cleaning agent.
Preferably, non-combustible cleaning agents should be used.
The choice of the appropriate cleaning agent depends on which parts of the spray
gun have to be cleaned and which product has to be removed. When cleaning the
spray gun only use non-polar cleaning agents to prevent conductive residues on the
surface of the spray gun. Should it however, be necessary to use a polar cleaning agent,
all residues of this cleaning agent have to be removed by using a non-conductive and
non-polar cleaning agent, once the cleaning is fi nished.
Ensure that no electrical component is cleaned with nor even immersed into solvent.
An explosive gas/air mixture forms in closed tanks.
When cleaning devices with solvents, never spray into a closed tank.
Only use electrically conductive tanks for cleaning liquids.
The tanks must be grounded.