EDITION 07/2014
OPERATING MANUAL
8. Close return valve (17).
9. Point the gun, without nozzle, into tank (18) and open it.
10. Slowly open the ball valve (11).
11. Close ball valve (11) as soon as pure working product starts coming from the gun.
12. When there is no pressure remaining in the system, close the gun.
13. Secure the gun.
14. Dispose of the contents of the tank (18) according to the local regulations.
7.3.2
START-UP FOR SPRAYING AIRCOAT
1. Secure gun and insert the desired nozzle into the gun.
2. Set pump (4) to about 8 Mpa; 80 bar; 1,160 psi operating pressure and start up
control unit (13).
3. Spraying (pull trigger).
4. Adjust the spray pressure at the paint pump according to the nozzle and object
being sprayed
5. Now open AirCoat air (6), approx. 0.01-0.25 MPa; 1-2.5 bar; 14,5-36 psi, and adjust for
the optimal atomization.
For round-jet method:
6. By turning the nozzle nut, the atomizing air jet can additionally
be adjusted.
Notes:
Do not turn the nozzle nut until it is fl ush with the nozzle body.
There must be play for the atomizing air between the nozzle nut
and the nozzle body.
The air adjustment at the back of the gun does not aff ect the
spray pattern in this process.
For fl at-jet method:
7. Change the width of the spray jet by turning the air adjustment
on the back of the spray gun or by appropriate selection of the
nozzle.
ORDER NUMBER DOC 2344500
B_03192
B_03159
39