7.3
WORK
7.3.1
FILLING WITH WORKING PRODUCT
1. Place an empty tank (18) under the return tube (8) (see picture B_03158).
2. Place suction hose (7) in the tank with working product (19).
Note:
If the pump is equipped with a rigid suction system, it should only be dipped in into
the working product up to the middle of the inlet housing at the maximum!
3. Adjust the pressure regulator (12) to approx. 0.05 MPa; 0.5 bar; 7.25 psi.
4. Open return valve (17).
5. Slowly open the ball valve (11).
6. Adjust the air pressure on the pressure regulator (12) so that the pump runs smoothly.
7. Close ball valve (11) as soon as pure working product starts coming from the return
tube (8).