8. Screw preassembled union nut (12) to gun (1) and tighten by hand.
9. Switch the product pressure back on.
10. Turn the trigger lock (14) to the spraying position and briefl y pull the trigger.
11. When the blockage has been fl ushed out, secure the gun with the trigger lock.
12. Relieve the pressure of gun and device.
13. Unscrew union nut (12).
14. Remove air cap (10) and push ACF5000 nozzle (11) out of the air cap by hand.
Clean ACF5000 nozzle and insert it in the spraying position into the valve housing.
15. Put the air cap (10) on the nozzle (11) and pay attention to the position of the guide
surfaces (X).
16. Screw union nut with attached nozzle guard (9) to the gun body and make sure that
the air cap horns lie in the designated recess (Y).
17. Before tightening with the air cap horns (Y), set the desired jet level and then tighten
the union nut to stop by hand.
18. Switch the product pressure and the air pressure back on.
19. Switch on the control unit.
Y
9
ACF5000 nozzle in
spray position
ACF5000 nozzle in
cleaning position
ORDER NUMBER DOC 2344500
X
Y
11
10
1
14
B_03211
12
12