7.3.6

REPLACING THE AIRCOAT FLAT JET NOZZLES

1.
Switch off control unit.
2.
Relieve pressure from the gun (1) and from the device!
3.
Secure the spray gun (1) using the trigger lock.
4.
Unscrew union nut (12) and remove air cap (10).
5.
Remove ACF5000 AirCoat nozzle (11) and treat it with cleaning agent until all traces
of paint have been removed.
Defective AirCoat nozzle!
Insuffi cient paint application quality.
Do not use sharp-edged objects to treat carbide on the AirCoat nozzle.
6.
Insert new ACF5000 nozzle (11) into the valve housing.
7.
Put the air cap (10) on the nozzle (11) and pay attention to the position of the guide
surfaces.
8.
Screw union nut with attached nozzle guard (9) to the gun body and make sure that
the air cap horns lie in the designated recess (Y).
9.
Before tightening with the air cap horns (Y), set the desired jet level and then tighten
the union nut to stop by hand.
7.3.7

CLEANING OF THE NOZZLE PARTS

The ACF5000 AirCoat nozzles (11), the nozzle inserts (3) and the nozzle screw connection
(7) can be placed in a cleaning solvent recommended by the lacquer manufacturer.
All other nozzle parts may not be put into cleaning solvent.
Clean these parts with a cleaning solvent recommended by the lacquer manufacturer and
dry with a cloth or blow gun.
7.3.8

ELIMINATE NOZZLE CLOGGING

1. Switch off control unit.
2. Relieve the pressure of gun and device.
3. Secure the spray gun (1) using the trigger lock (14).
4. Unscrew complete union nut (12) with air cap (10) and ACF5000 nozzle (11).
5. Remove air cap (10).
6. Push ACF 5000 nozzle (11) out of air cap (10) by hand, reverse it and put it into the air
cap (10) with the nozzle tip towards the rear.
Pay attention to the position of the guide surfaces (X).
7. Insert air cap (10) with integrated ACF5000 nozzle (11) into the union nut (9).
Make sure that the air cap horns (Y) lie in the recess of the nozzle guard.