Grounding - WAGNER GM 5000EAC F Operating Manual

Electrostatic aircoat spray gun for manual operation and for flat or round jet nozzles
Hide thumbs Also See for GM 5000EAC F:
Table of Contents

Advertisement

EDITION 07/2014
OPERATING MANUAL
6.4.5

GROUNDING

Perfect grounding of all conductive parts such as fl oors, walls, roofs is important for
optimum coating and safety. Barriers, work pieces, transport devices, coating product
tank, coating product supply or construction parts in the spray area with exception of the
high-voltage parts during normal operation.
Parts of the booth must be grounded in accordance with EN 12215.
Discharge of electrostatically charged components in atmospheres
containing solvents!
Explosion hazard from electrostatic sparks or fl ames.
Heavy paint mist if grounding is insuffi cient!
Danger of poisoning.
Insuffi cient paint application quality.
A poorly grounded work piece causes:
very bad wrap around,
uneven coating,
back spraying to the spray gun, i.e. contamination.
Prerequisites for perfect grounding and coating are:
Clean work piece suspension.
Grounding of spray booth, conveyor system and suspension on the building side in
accordance with the operating instruction or the manufacturer's information.
Grounding of all conductive parts within the working area.
The grounding resistance of the work piece may not exceed 1 MΩ (Megohm).
Note:
Resistance to ground measured at 500 V or 1,000 V.
Connect the control unit to the system ground.
ORDER NUMBER DOC 2344500
WARNING
Ground all device components.
Ground the work pieces to be coated.
WARNING
Ground all device components.
Ground the work pieces to be coated.
30