EDITION 07/2014
OPERATING MANUAL
3
2
SW5/ 0.4 - 0.5 Nm
B_03202
Ensure the correct
4
insertion position.
Ensure the correct
insertion position.
ORDER NUMBER DOC 2344500
SW5
4
2
1
Set measure X with withdrawal nut and then
fasten it with the threaded pin (SW2).
X = 123 ±0.1
Push the valve rod unit and the complete packing
together.
SW6
0.4 -
Screw the valve rod unit and the complete packing
0.5 Nm
together.
Only as required:
2
Remove the valve rod unit.
Tighten the complete packing.
Carefully insert the valve rod unit and mount the
complete clamping screw (1) with assembly tool (5).
0.5 Nm
5
Slightly tighten AC valve
tip by hand using an
assembly tool
(Order No. 2309368).
1.8 Nm
Assembly tool (Order No. 2325263)
X
5
Note:
Use assembly tool, socket or
SW9
ring spanner (no wrench).
SW2
1Nm
B_03203