WAGNER GM 5000EAC F Operating Manual page 47

Electrostatic aircoat spray gun for manual operation and for flat or round jet nozzles
Hide thumbs Also See for GM 5000EAC F:
Table of Contents

Advertisement

EDITION 07/2014
OPERATING MANUAL
Exploding gas / air mixture!
Danger to life from fl ying parts and burns.
Gun fl ushing
1. Switch off control unit.
2. Ensure that the product pressure is relieved and shut off the air supply to the gun.
3. Connect the cleaning agent supply.
With round jet nozzle fi tted:
4. By means of nozzle spanner, loosen nozzle insert by 1/2 turn.
5. Actuate the trigger. Flush the gun thoroughly.
6. Relieve the pressure from gun and unit!
7. Re-tighten the nozzle insert.
8. Clean the spray gun body with a cleaning agent recommended by the manufacturer
and dry with a cloth or blow gun.
With fl at jet nozzle fi tted:
4. Dismount AirCoat nozzle and clean separately (see Chapter 7.3.7).
5. Actuate the trigger. Flush the gun through thoroughly.
6. Relieve the pressure from gun and unit!
7. Clean the spray gun body with a cleaning agent recommended by the lacquer
manufacturer and dry with a cloth or blow gun.
Flushing agent in the air duct!
Functional faults caused by swollen seals.
Discharge current to ground -> no high-voltage
Always point the spray gun down when cleaning.
Ensure that neither paint nor cleaning agent enters the air duct.
When taking a break from work or when stored for a longer period, the spray gun
should be positioned with the adapter pointing downwards.
ORDER NUMBER DOC 2344500
DANGER
Never spray into a closed tank.
Ground the tank.
NOTICE
B_03453
47