EDITION 07/2014
OPERATING MANUAL
8.6.2
AIR TEST
Connect test or air hose to the spray gun and switch on mains pressure to a maximum of
0.8 MPa; 8 bar; 116 psi.
Checking the air valve
The air valve must switch on and off correctly.
Test up to approx. 0.8 MPa; 8 bar; 116 psi.
Air tightness
With the trigger unactuated, test for air tightness at the points marked in the illustration:
8.6.3
PRODUCT PRESSURE TEST
Connect high-pressure hose to the spray gun.
Test the spray gun for tightness with solvent or spray oil (e.g. Macrol 52) and a maximum
pressure of 25 MPa; 250 bar; 3,626 psi.
Observe the following gun components:
Product connection, nozzle body, product valve (no after-spraying).
Exploding gas / air mixture!
Danger to life from fl ying parts and burns.
ORDER NUMBER DOC 2344500
B_03213
DANGER
Never spray into a closed tank.
Ground the tank.
60