YOKOGAWA WT200 User Manual page 143

Digital power meter
Table of Contents

Advertisement

13.1 Commands
HA/HA?
Determines whether or not to turn ON
the harmonic analysis function or
queries the current setting.
Syntax
HA m<terminator>
"m" indicates whether the harmonic
analysis function or normal measurement
function is set.
m=
0:Normal measurement
1:Harmonic analysis
Query
HA?<terminator>
Example
HA1
Description • Parameter error 12 will occur if "m" is set to an
illegal value.
• When integration is in progress or being
aborted, harmonic analysis cannot be
performed; error 13 will occur.
• Integration cannot be started when the
harmonic analysis function is in progress;
error 16 will occur.
• While recalling or storing is in progress,
execution error 19 will occur.
HE/HE?
Determines the element of the harmonic
analysis function or queries the current
setting.
Syntax
HE m<terminator>
m=
1:Element 1
Query
HE?<terminator>
Example
HE1
Description • Parameter error 12 will occur if "m" is set to an
illegal value.
• While recalling or storing is in progress,
execution error 19 will occur.
IC/IC?
Sets the integration mode or queries the
current setting.
Syntax
IC m<terminator>
"m" indicates one of the following
integration modes.
m=
0:Normal integration mode
1:Continuous integration mode
Query
IC?<terminator>
Example
IC1
Description • Parameter error 12 will occur if "m" is set to an
illegal value.
• Changing the integration mode is not allowed
while integration is in progress; execution
error 13 will occur.
• If continuous integration mode is selected,
make sure that the timer preset time is set to
a value larger than "0".
• If normal integration mode is selected, set the
timer preset time to any desired value.
• While recalling or storing is in progress,
execution error 19 will occur.
IG/IG?
Sets the integration type or queries the
current setting.
Syntax
IG m<terminator>
"m" indicates the integration type.
m=
0:Standard
1:Advanced
13-4
Query
IG?<terminator>
Example
IG0
Description • Parameter error 12 will occur if "m" is set to an
illegal value.
• Cannot be changed while integration is in
progress. Execution error 13 will occur.
• While recalling or storing is in progress,
execution error 19 will occur.
IM/IM?
Specifies which causes will be allowed
to generate a status byte or queries the
current setting.
Syntax
IM m<terminator>
"m" is assigned as follows (0 ≤ m ≤ 15).
m=
1:Computation end
2:Integration end
4:Syntax error
8:OVER
Query
IM?<terminator>
Example
IM15
Description • Parameter error 12 will occur if "m" is set to an
illegal value.
• If more than one of these causes is to be
allowed, set "m" to the sum of their individual
"m" values. For instance, if all causes are to
be allowed, set "m" to 15 (=1+2+4+8).
IP
Stops integration.
Syntax
IP<terminator>
Description • If an attempt is made to stop integration when
integration has already been interrupted
(stopped), execution error 44 will occur.
• While recalling or storing is in progress,
execution error 19 will occur.
IR
Resets integration.
Syntax
IR<terminator>
Description • If an attempt is made to reset integration while
integration is in progress, execution error 45
will occur.
• While recalling or storing is in progress,
execution error 19 will occur.
IS
Starts integration.
Syntax
IS<terminator>
Description • If an attempt is made to start integration when
integration is already in progress, execution
error 42 will occur.
• If a voltage or current peak overflow, or
overrange takes place when an attempt is
made to start integration, execution error 46
will occur, and integration will not be started.
• While recalling or storing is in progress,
execution error 19 will occur.
KH/KH?
Sets MAX hold function or queries the
current setting.
Syntax
KH m<terminator>
"m" indicates whether the MAX hold
function is ON or OFF.
m=
0:OFF
1:ON