Malfunctions
Valve faults
Tab. 35 Fault clearance of valve faults
9.2.4

Communication errors

The error codes for communication errors are returned by the product as return values after incorrect
read and write commands.
Error
Description
code
E0
Ready for operation, no error
E34
Invalid index
E35
Invalid subindex
E36
Read request cannot be processed
E37
Write request cannot be processed
E41
Specified value falls below the minimum
value
E42
The specified value exceeds the maximum
value
E43
Incorrect transfer value
E44
Data type incorrect
E93
General syntax error
E94
Syntax error index (variable x)
E95
Syntax error subindex (variable y)
E96
Syntax error value
28
Inspection interval
Remedy
Error in current con-
sumption during pickup
phase
Error in current con-
sumption during the
holding current phase
 400 mA (
>
Check valve and wiring and
replace if necessary
9.2.1 Resetting the
è
active error bit
Fault clearance
Check transfer command and use valid
index
Check transfer command and use valid
subindex
Check and correct input
Check and correct input
Check and correct value
Check and correct value
Check and correct the transfer value
Use correct data type
Check and correct the ASCII structure of the
input
Check and correct index and value
Check and correct subindex and value
Check and correct value
Festo — VAEM-V-S8EPRS2 — 2020-07
 1 A (
 4 ms)
>
>
 10 ms)
>

Advertisement

Table of Contents
loading