Counters
Static (Steady-State) Object Number: 20
Change Event Object Number: 22
Static Variation reported when variation 0 requested: 1 (32-Bit Counter with Flag)
Change Event Variation reported when variation 0 requested: 1 (32-Bit Counter Event with Flag)
Frozen Counters
Static (Steady-State) Object Number: 21
Change Event Object Number: 23
Static Variation reported when variation 0 requested: 1 (32-Bit Frozen Counter with Flag)
Change Event Variation reported when variation 0 requested: 1 (32-Bit Frozen Counter Event with Flag)
Point
Description
Index
25 E5 Counter
26 E6 Counter
27 E7 Counter
28 E8 Counter
29 E9 Counter
30 E10 Counter
31 E11 Counter
32 E12 Counter
33 E13 Counter
34 E14 Counter
35 E15 Counter
36 E16 Counter

5.3.5 Analog Inputs

The following table lists Analog Inputs (Object 30). It is important to note that 16-bit and 32-bit variations of Analog
Inputs, Analog Output Control Blocks, and Analog Output Statuses are transmitted through DNP as signed numbers.
The "Default Deadband," and the "Default Change Event Assigned Class" columns are used to represent the absolute
amount by which the point must change before an Analog change event will be generated, and once generated in
which class poll (1, 2, 3, or none) will the change event be reported.
The default analog input event buffer size is set 30. The analog input event mode is set to Most Recent, only most
recent event for each point is stored.
Analog inputs are by default returned in a class zero interrogation.
Note, not all points listed here apply to all builds of devices.
© 2017 Siemens Protection Devices Limited
Chapter 4 - Data Communications Definitions
or 2 (16-Bit Counter with Flag)
or 5 (32-Bit Counter w/o Flag)
or 6 (16-Bit Counter w/o Flag)
or 2 (16-Bit Counter Event with Flag)
or 5 (32-Bit Counter Event with Flag and Time)
or 6 (16-Bit Counter Event with Flag and Time)
or 2 (16-Bit Frozen Counter with Flag)
or 5 (32-Bit Frozen Counter with Flag and Time)
or 6 (16-Bit Frozen Counter with Flag and Time)
or 9 (32-Bit Frozen Counter w/o Flag)
or 10 (16-Bit Frozen Counter w/o Flag)
or 2 (16-Bit Frozen Counter Event with Flag)
or 5 (32-Bit Frozen Counter Event with Flag and Time)
or 6 (16-Bit Frozen Counter Event with Flag and Time)
Counter
Default
Change
Default
Default
Event
Variation
Variation
Assigned
Static
Event
Class
Object 20
Object 22
(1, 2, 3
or none)
0,3
5
1
0,3
5
1
0,3
5
1
0,3
5
1
0,3
5
1
0,3
5
1
0,3
5
1
0,3
5
1
0,3
5
1
0,3
5
1
0,3
5
1
0,3
5
1
Frozen Counter
Default
Change
Default
Event
Variation
Assigned
Static
Class
Object 21
(1, 2, 3
or none)
1
0,2
9
1
0,2
9
1
0,2
9
1
0,2
9
1
0,2
9
1
0,2
9
1
0,2
9
1
0,2
9
1
0,2
9
1
0,2
9
1
0,2
9
1
0,2
9
Chapter 4 - Page 79 of 96
Default
Variation
Event
Object 23
1
1
1
1
1
1
1
1
1
1
1
1