Implementation Table - Siemens Argus 7SR21 Technical Manual

Overcurrent relay
Hide thumbs Also See for Argus 7SR21:
Table of Contents

Advertisement

7SR220 Technical Manual

5.2 Implementation Table

The following table identifies which object variations, function codes, and qualifiers the Triangle MicroWorks, Inc.
DNP 3.0 Slave Source Code Library supports in both request messages and in response messages. For static (non-
change-event) objects, requests sent with qualifiers 00, 01, 06, 07, or 08, will be responded with qualifiers 00 or 01.
Requests sent with qualifiers 17 or 28 will be responded with qualifiers 17 or 28. For change-event objects, qualifiers
17 or 28 are always responded.
In the table below, text shaded as 00, 01 (start stop) indicates Subset Level 3 functionality (beyond Subset Level 2).
In the table below, text shaded as 07, 08 (limited qty) indicates functionality beyond Subset Level 3.
OBJECT
Object
Variation
Number
1
0
1
1
2 (default -
1
see note 1)
Binary Input Change
2
0
Binary Input Change
2
1
2 (default -
Binary Input Change
2
see note 1)
Binary Input Change
2
3
3
0
1 (default -
3
see note 1)
3
2
Double Bit Input Change
4
0
Double Bit Input Change
4
1
Double Bit Input Change
4
2
3 (default -
Double Bit Input Change
4
see note 1)
10
0
Chapter 4 - Page 56 of 96
Function Codes
Description
(dec)
Binary Input
1 (read)
- Any Variation
22 (assign class)
Binary Input
1 (read)
Binary Input
1 (read)
with Status
1 (read)
- Any Variation
1 (read)
without Time
1 (read)
with Time
1 (read)
with Relative Time
Double Bit Input
1 (read)
- Any Variation
22 (assign class)
Double Bit Input
1 (read)
Double Bit Input
1 (read)
with Status
1 (read)
- Any Variation
1 (read)
without Time
1 (read)
with Time
1 (read)
with Relative Time
Binary Output
1 (read)
- Any Variation
22 (assign class)
REQUEST
(Library will parse)
Qualifier Codes
(hex)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
06 (no range, or all)
07, 08 (limited qty)
06 (no range, or all)
07, 08 (limited qty)
(unsol. resp)
06 (no range, or all)
07, 08 (limited qty)
(unsol. resp)
06 (no range, or all)
07, 08 (limited qty)
(unsol. resp)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
06 (no range, or all)
07, 08 (limited qty)
06 (no range, or all)
07, 08 (limited qty)
(unsol. resp)
06 (no range, or all)
07, 08 (limited qty)
(unsol. resp)
06 (no range, or all)
07, 08 (limited qty)
(unsol. resp)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
© 2017 Siemens Protection Devices Limited
RESPONSE
(Library will respond with)
Function
Qualifier Codes
Codes
(hex)
(dec)
00, 01 (start-stop)
129
17, 28 (index
(response)
- see note 2)
00, 01 (start-stop)
129
17, 28 (index
(response)
- see note 2)
129
(response)
17, 28 (index)
130
129
(response)
17, 28 (index)
130
129
(response)
17, 28 (index)
130
00, 01 (start-stop)
129
17, 28 (index
(response)
- see note 1)
00, 01 (start-stop)
129
17, 28 (index
(response)
- see note 1)
129
(response)
17, 28 (index)
130
129
(response)
17, 28 (index)
130
129
(response)
17, 28 (index)
130

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Argus 7sr22

Table of Contents