Table 1.5-2 Ordering Information - 7Sr22 Directional Overcurrent - Siemens Argus 7SR21 Technical Manual

Overcurrent relay
Hide thumbs Also See for Argus 7SR21:
Table of Contents

Advertisement

7SR210 & 7SR220 Description of Operation
Table 1.5-2
Ordering Information – 7SR22 Directional Overcurrent
Product description
Variants
Protection Product Family
Overcurrent - Directional
Relay Type
Case, I/O and Fascia
E6 case, 5 CT, 4 VT, 3 Binary Inputs, 6 Binary Outputs, 8 LEDs
E8 case, 5 CT, 4 VT, 13 Binary Inputs, 14 Binary Outputs, 16 LEDs
E8 case, 5 CT, 4 VT, 13 Binary Inputs, 14 Binary Outputs, 8 LEDs + 6 keys
E12 case, 5 CT, 4 VT, 33 Binary Inputs / 14 Binary Outputs, 32 LEDs
E12 case, 5 CT, 4 VT, 33 Binary Inputs / 14 Binary Outputs, 16 LEDs, 12 keys
Measuring input
1 A or 5 A, 40 V to 160 V, 50 Hz or 60 Hz
Auxiliary voltage
PSU Rated: 30 to 220V DC. Binary Input threshold 19V DC (Rated: 24-250V DC)
PSU Rated: 30 to 220V DC. Binary Input threshold 88V DC (Rated: 110-250V DC)
PSU Rated: 24-250V DC / 100-230V AC. Binary Input threshold 19V DC (Rated: 24-250V DC)
PSU Rated: 24-250V DC / 100-230V AC. Binary Input threshold 88V DC (Rated: 110-250V DC)
Spare
Communication Interface
Standard version - included in all models, USB front port, RS485 rear port
Standard version - plus additional rear F/O ST connectors (x2) and IRIG-B
Standard version - plus additional rear RS485 and IRIG-B
Standard version - plus additional rear RS232 and IRIG-B
Standard version - plus additional rear Electrical Ethernet RJ45 (x2)
Standard version - plus additional rear Optical Ethernet Duplex (x2)
Protocol
IEC 60870-5-103 and Modbus RTU (user selectable)
IEC 60870-5-103 and Modbus RTU and DNP 3.0 (user selectable)
IEC 60870-5-103 and Modbus RTU and DNP 3.0 (user selectable) and IEC61850
Spare
Protection Function Packages
Standard version - included in all models
21FL
Fault Locator
21LB
Load Blinder
1)
Under/overvoltage
27/59
32
Power
32S
Sensitive Power
37
Undercurrent
1)
Ground Undercurrent
37G
SEF Undercurrent
1)
37SEF
46BC
Broken conductor/load unbalance
46NPS
Negative phase sequence overcurrent
1)
Negative phase sequence voltage
47
49
Thermal overload
50
Instantaneous phase fault overcurrent
50BF
Circuit breaker fail
50G/50N
Instantaneous earth fault
50 AFD
Arc Flash Detector
51V
Voltage dependent overcurrent
55
Power factor
59N
Neutral voltage displacement
60CTS
CT supervision
60CTS-I
CT supervision
60VTS
VT supervision
64H
High impedance REF
67/50
Directional instantaneous phase fault overcurrent
67/50G
Directional instantaneous earth fault/SEF
67/50N
67/51
Directional time delayed phase fault overcurrent
67/51G
Directional tIme delayed earth fault/SEF
67/51N
74TC/CCS Trip & close circuit supervision
81
Under/overfrequency
81HBL2
Inrush Detector
81HBL5
Overfluxing
86
Lockout
Cold load pickup
Programmable logic
CB Control
Standard version - plus
79
Autoreclose
Standard version - plus
79 + 25
Autoreclose + Check Sync
Additional Functionality
No additional functionality
Spare
1)
5CT is configured as 3PF + EF/SEF + EF/SEF (user selectable setting).
Export Data
HS: 8536900
ECCN: N
AL: N
Unrestricted Page 12 of 94
7
1)
Order No.
S
R
2
2
0
-
2
2
0
2
3
4
5
6
2
A
B
M
N
©2018 Siemens Protection Devices Limited
A
-
0
A
0
C
A
1
2
3
4
7
7
8
7
1
2
7-8
7
0
C
D
E
A
0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Argus 7sr22

Table of Contents