ABB ACH550-UH User Manual page 225

Ach550 series, hvac drives (1...550 hp), e-clipse bypass drives (1...400 hp), packaged drives with disconnect (1...550 hp)
Hide thumbs Also See for ACH550-UH:
Table of Contents

Advertisement

ACH550-UH User's Manual
Point
#
{91}
{92}
{93}
{94}
{95}
{96}
{97}
{98}
{99}
a. Points not listed are not used in this application.
b. A single value in a column means that the value is the same in English units and in SI units.
c. Point numbers that appear in brackets { } may be unbundled at the field panel.
Detailed point descriptions
1
CTRL ADDRESS The FLN address of the drive. It can be set by FLN and by
2
APPLICATION
3
FREQ OUTPUT
4
PCT OUTPUT
5
SPEED
6
CURRENT
7
TORQUE
8
POWER
9
DRIVE TEMP
Subpoint Name
Type
LAI
PREV FAULT 1
LAI
PREV FAULT 2
LDI
OK.FAULT
LDO
RESET FAULT
LAO
MBOX PARAM
LAO
MBOX DATA
LDO
MBOX READ
LDO
MBOX WRITE
LAO
ERROR STATUS -
Point
the panel.
The Application ID for FLN on the ACH550. This ID is
assigned by Siemens for each unique application. It
correlates directly to a particular point list approved at the
time of release. Therefore, this point list shall remain fixed
once approval is granted. Any changes to the point list shall
require a new Application ID and re-approval by Siemens.
The Application ID assigned to ACH550 is 2734.
The output frequency applied to the motor, in Hertz.
The ratio of output frequency or speed to the corresponding
maximum rating, depending on control mode.
• For scalar mode, it is the ratio of Output Frequency
(parameter 0103) to Maximum Frequency (parameter
2008).
• For speed mode, it is the ratio Speed (parameter 0102) to
Maximum Speed (2002).
The calculated speed of the motor, in RPM.
The measured output current.
The calculated output torque of the motor as a percentage of
nominal torque.
The measured output power in KW. The FLN point definition
also supports horsepower by selecting English units.
The measured heatsink temperature, in
definition also supports
FLN Point Database
Factory
Engr.
Slope
Default
Units
(SI Units)
-
-
1
-
-
1
OK
-
1
NO
-
1
-
-
1
-
-
1
DONE
-
1
DONE
-
1
-
1
FLN Detailed Point Descriptions
Description
F by selecting English units.
°
Intercept
On Text
0
-
0
-
0
FAULT
0
RESET
0
-
0
-
0
READ
0
WRITE
0
-
Parameter
5302
0103
None. This
ratio is
calculated
by the FLN
application.
0102
0104
0105
0106
C. The FLN point
0110
°
Embedded fieldbus
1-221
Off Text
-
-
OK
NO
-
-
DONE
DONE
-
Drive

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents