Connecting To Encoder Input Terminals; A-3-1 Wiring To Encoder Input Terminals; A-3-2 Settings For Encoder Input Terminals - Omron NX701-1 User Manual

Machine automation controller nj/nx-series cpu unit
Hide thumbs Also See for NX701-1:
Table of Contents

Advertisement

Appendices
A-3
Connecting to Encoder Input
Terminals
This appendix describes connections to an OMRON GX-series EtherCAT Slave Encoder Input Termi-
nals.
A-3-1
Wiring to Encoder Input Terminals
Encoder Input Terminals are connected using EtherCAT communications. Refer to the NJ/NX-series
CPU Unit Built-in EtherCAT Port User's Manual (Cat. No. W505) for information on the connection
methods.
A-3-2
Settings for Encoder Input Terminals
This section outlines the Encoder Input Terminal settings that are used when connected to OMRON
GX-series GX-EC0211/EC0241 Encoder Input Terminals (i.e., the applicable Encoder Input Terminals
for the MC Function Module). Refer to the GX-series EtherCAT Slave Units User's Manual (Cat. No.
W488) for detailed information on the Encoder Input Terminals.
Recommended Encoder Input Terminals
All of the functions of an encoder axis of the MC Function Module can be used for Encoder Input Termi-
nals with the unit versions that are given in the following table.
Manufacturer
OMRON
OMRON
Additional Information
• Only the OMRON GX-EC0211/EC0241 can be used for encoder axes of EtherCAT slaves.
• Unit version 1.0 of the OMRON GX-EC0211/EC0241 can also be used for encoder axes, but
they are not Sysmac devices. When you use unit version 1.0, do not set the node address
switches to 00. If you set them to 00, a network configuration error occurs. Refer to the GX-
series EtherCAT Slave Units User's Manual (Cat. No. W488) for detailed information on func-
tions.
Refer to the NJ/NX-series CPU Unit Software User's Manual (Cat. No. W501) for details on
Sysmac devices.
External Input Signals
When all of the functions of an encoder axis are used for an Encoder Input Terminal, the following input
signals are used at the Encoder Input Terminal.
• Counter A phase
• Counter B phase
• Counter Z phase
• Latch Inputs (A/B)
A-22
Compatible models
GX-EC0211
GX-EC0241
NJ/NX-series CPU Unit Motion Control User's Manual (W507)
Applicable unit versions
Unit version 1.1 or later
Unit version 1.1 or later

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx102-1Nx102-90Nj501Nj301-1Nx1p2-1Nx1p2-90 ... Show all