Omron NX701-1 User Manual page 261

Machine automation controller nj/nx-series cpu unit
Hide thumbs Also See for NX701-1:
Table of Contents

Advertisement

Direction
Negative direction
Current direction
No direction specified
Example for Shortest Way
The following example illustrates when positioning is performed towards a target position of −20 when
the command current position is 50.
Modulo maximum
position setting
value: 100
0
Modulo minimum
position setting
value: −70
Additional Information
Moves in the same direction as the Current Direction specification if the travel distance is the
same in the positive and negative directions.
Example for Positive Direction
The following example illustrates when positioning is performed towards a target position of −20 when
the command current position is 50.
Modulo maximum
position setting
value: 100
0
Modulo minimum
position setting
value: −70
NJ/NX-series CPU Unit Motion Control User's Manual (W507)
Motion starts in the negative direction.
Motion starts in the same direction as the previous operation.
Motion starts in the direction that does not pass through the upper and lower limits of
the ring counter. With this direction specification, you can specify a target position that
exceeds the upper or lower limits of the ring counter. If that occurs, relative positioning
is performed using the difference between the target position and the command current
position as the target distance. This enables you to perform multi-turn positioning on
the ring counter.
Command current position:
50
Target position:
−20
Moves in negative direction.
Command current position:
50
Target position:
−20
9 Motion Control Functions
Operation
Target position:
−20
Target position:
−20
Moves in positive direction.
9
9-39