Settings For Judgment Output - Omron ZW-C1*T User Manual

Displacement sensor zw series confocal fiber type
Hide thumbs Also See for ZW-C1*T:
Table of Contents

Advertisement

Settings for Judgment Output

The following describes the settings for outputting the judgment results from the judgment output of the 20-pole
terminal block.
Assigning judgment output
Set the task for which to output the judgment results.
The judgment results for the selected task are output from the following output terminals of the 20-pole terminal
block.
HIGH1/PASS1/LOW1
Item
Setting item
Judgment
Output object
1
Set the operating mode to the FUN mode.
3-3 Switching operation modes p.57
 Explorer pane
 Edit pane
 I/O Setting Screen
2
Select the task from [Output object].
Note
Judgment output can also be assigned with key operations on the Sensor Controller.
Assigning judgment output p.271
ZW User's Manual
Setting value
TASK1/TASK2/TASK3/TASK4
: [Bank] | [(Bank Data Name)] (double click)
: [I/O Settings] icon (
: [Judgment]
Description
Select the task for which to output the judgment result.
)
Parallel I/O connection