Omron ZW-C1*T User Manual page 217

Displacement sensor zw series confocal fiber type
Hide thumbs Also See for ZW-C1*T:
Table of Contents

Advertisement

Measurement
TASK1
setting
[TASK1]
[MEAS]
(cont'd)
(cont'd)
TASK2
[TASK2]
TASK3
[TASK3]
TASK4
[TASK4]
ZW User's Manual
Output
Scaling
[OUTPUT]
[SCALE]
Hold
[HOLD]
Zero reset
[ZERO]
Threshold
Teaching
[JUDGE]
[TEACH]
Direct
[DIRECT]
(Same content as TASK1)
(Same content as TASK1)
(Same content as TASK1)
Setting
Option/Setting Range
Auto
[AUTO]
One-point
scaling
[1PT]
Direction
*
Forward [FWD]
/Reverse [REV]
[DIR]
Two-point
scaling
[2PT]
Manual
[MANUAL]
Span
-2.0000 to 2.0000 (default value:
[SPAN]
1.0000)
Offset
-999.999999 to 999.999999 mm
[OFFSET]
(default value: 0)
Thick
[THICK]
Off
[OFF]*
*
Off [OFF]
/Peak [PEAK]/
Bottom [BOTTOM]/Peak to peak[P-P]/
Type
Auto peak [A.PEAK]/
[TYPE]
Auto bottom [A.BOTTM]/
Auto peak to peak [A.P-P]/
Average [AVE]/Sampling [SAMPLE]
Trigger
Timing [TIMING]
[TRIG]
[SELF-U]/Self down trigger [SELF-D]
Trigger level
-999.999999 to 999.999999 mm
[LEVEL]
(default value: 0)
Trigger
0 to 999.999999 mm
Hysteresis
(default value: 0.05% of measuring
[HYS]
range)
Delay
*
Off [OFF]
/On [ON]
[DELAY]
Delay time
1 to 5000 ms (default value: 1 ms)
[DLY.TIM]
Sampling time
1 to 5000 ms (default value: 100 ms)
[SMP.TIM]
Type
Real value [REAL]
[TYPE]
Hold value [HOLD]
Offset
-999.999999 to 999.999999 mm
[OFFSET]
(default value: 0)
Status
Off [OFF]/On [ON]
[STATUS]
High
-999.999999 to 999.999999 mm
threshold
(default value: +25% of measuring
[H.JUDGE]
range)
-999.999999 to 999.999999 mm
Low threshold
(default value: -25% of measuring
[L.JUDGE]
range)
High
-999.999999 to 999.999999 mm
threshold
(default value: +25% of measuring
[H.JUDGE]
range)
-999.999999 to 999.999999 mm
Low threshold
(default value: -25% of measuring
[L.JUDGE]
range)
Search from Menu Tree
Pages
p.240
p.244
*
/Self up trigger
p.245
p.247
*
/
p.250
p.249
*
p.248
p.257
p.259
215

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents