Settings for Bank Control

This section describes the settings for controlling banks by using parallel I/O.
Selecting banks
The bank is selected in combinations of the bank select input signals (BANK_SEL1 to 3).
Bank selection input 1
Bank selection input 2
(BANK_SEL1)
(BANK_SEL2)
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
Important
• Bank switching is begun 0.2 seconds after the input state changes.
• At most it takes about 100ms to switch banks.
• During bank switching, the BUSY output becomes ON.
• If the bank mode is set to [JUDGE], the bank cannot be switched at the external signal input because the number of
banks increases to 32.
Outputting the currently selected bank number
The currently selected bank number is output.
The output bank number depends on the combination of the bank number output signals (BANK_OUT1 to 3).
Bank number output 1
Bank number output 2
(BANK_OUT1)
(BANK_OUT2)
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
ZW User's Manual
Bank selection input 3
Selected bank
(BANK_SEL3)
OFF
BANK1
OFF
BANK2
OFF
BANK3
OFF
BANK4
ON
BANK5
ON
BANK6
ON
BANK7
ON
BANK8
Bank number output 3
Output bank
(BANK_OUT3)
OFF
BANK1
OFF
BANK2
OFF
BANK3
OFF
BANK4
ON
BANK5
ON
BANK6
ON
BANK7
ON
BANK8
Parallel I/O connection