Omron ZW-C1*T User Manual page 124

Displacement sensor zw series confocal fiber type
Hide thumbs Also See for ZW-C1*T:
Table of Contents

Advertisement

Item
TriggerStartObject
TriggerStartConditions
TriggerStartValue1
TriggerStartValue2
TriggerStartDelay
TriggerEnd
TriggerEndType
TriggerEndObject
TriggerEndConditions
TriggerEndValue1
TriggerEndValue2
TriggerEndDelay
MaxSamplesPerFile
TargetDirectory
FilePrefix
122
Saving measured values in a file
Output items
TASK1
TASK2
TASK3
TASK4
TIMING
ZERO
BUSY
ENABLE
HIGH
PASS
LOW
EqualTo
NotEqualTo
AndMore
MoreThan
LessThan
AndLess
True (rising)
False (falling)
-999.999999 to 999.999999 mm
-999.999999 to 999.999999 mm
-999.999999 to 999.999999 mm
True
False
IO
DataSlope
DataWindowIn
DataWindowOut
DataSize
TASK1
TASK2
TASK3
TASK4
TIMING
ZERO
BUSY
ENABLE
HIGH
PASS
LOW
EqualTo
NotEqualTo
AndMore
MoreThan
LessThan
AndLess
True (rising)
False (falling)
-999.999999 to 999.999999 mm
-999.999999 to 999.999999 mm
-999.999999 to 999.999999 mm
1 to 999999999
Description
Indicates the target data for the trigger start condition.
Indicates the trigger start condition.
EqualTo: =
NotEqualTo: 
AndMore: 
MoreThan: >
LessThan: <
AndLess: 
True: Rising
False: Falling
Indicates the judgment value for the trigger start condition.
For data window (in/out), indicates the lower limit.
Indicates the judgment value for the trigger start condition.
For data window (in/out), indicates the upper limit.
Indicates the delay time for the trigger start condition.
Indicates whether the trigger end condition is "Enabled" or
"Disabled".
Indicates the trigger end condition.
IO: I/O result
DataSlope: Data slope
DataWindowIn: Data window (in)
DataWindowOut: Data window (out)
DataSize: Number of data points
Indicates the target data for the trigger end condition.
Indicates the trigger end condition.
EqualTo: =
NotEqualTo: 
AndMore: 
MoreThan: >
LessThan: <
AndLess: 
True: Rising
False: Falling
Indicates the judgment value for the trigger end condition.
For data window (in/out), indicates the lower limit.
Indicates the judgment value for the trigger end condition.
For data window (in/out), indicates the upper limit.
Indicates the delay time for the trigger end condition.
Indicates the number of samples in one file.
Indicates where the file is stored.
Indicates the prefix.