Omron ZW-C1*T User Manual page 163

Displacement sensor zw series confocal fiber type
Hide thumbs Also See for ZW-C1*T:
Table of Contents

Advertisement

Bank Switching
BANK_SEL input
(BANK_SEL1/2/3)
BANK_OUT output
(BANK_OUT1/2/3)
ON
BUSY output
OFF
ON
ENABLE output
OFF
Measurement
Item
T7
Input response time
T8
Bank switching time
T9
Measurement start response time
Explanation of operations
(1) The BANK_SEL signal is switched to the bank number to switch to.
(2) After the input response time, the measurement stops and the BUSY output is turned ON, then the bank
switching operation is started.
(3) After bank switching ends, the BUSY output is turned OFF and the BANK_ OUT output is switched.
(4) Measurement is restarted and the ENABLE output is turned ON.
ZW User's Manual
(1)
(2)
T7
T8
Clamp
Measurement
Min.
3×T0
(3)
(4)
T9
Measurement
Max.
200 ms
100 ms
Depends on the set conditions