RESET input
Name
RESET input
TIMING input
Name
TIMING input
LED OFF input
Name
LED OFF input
52-pole expansion connector
Binary output
Name
LED OFF input
GATE signal output
Name
GATE output
ZW User's Manual
Description
This resets all executing measurements and outputs.
While a RESET is being input, judgment output conforms to the non-measurement setting.
If this RESET input switches ON while the hold function is used, the state in effect before the
hold function was set will be restored.
Description
This timing input is for signal input from external devices. Use it for hold function timing.
Description
Turn off the measurement LED.
While LED OFF is being input, the analog output, binary output and judgment output conform to
the non-measurement setting.
Description
BINARY output This outputs the measurement result or judgment value as binary.
The measured value is output converted to 21 bits of binary data.
All the task judgment results can be output together.
Description
This is the timing signal for taking in binary data with external devices.
When the GATE signal is ON, take in the binary data.
Parallel I/O connection