Setting Output Conditions

Judgment output timing (timer)

The timing for judgment outputs can be adjusted to match the operation of external
devices.
Setting value
OFF
OFF-D (OFF delay)
ON-D (ON delay)
ZX-GT User's Manual
Description
Outputs the judgment as soon as the judgment result has been
confirmed. (default value)
Measured value
HIGH threshold
LOW threshold
HIGH output
ON
OFF
PASS output
ON
OFF
LOW output
ON
OFF
After the judgment result has been confirmed, delays the time required
for the PASS output to turn OFF by the time set to timer. (Also delays
turning OFF the HIGH and LOW outputs.)
Measured value
HIGH threshold
LOW threshold
HIGH output
ON
OFF
PASS output
ON
OFF
LOW output
ON
OFF
After the judgment result has been confirmed, delays the time required
for the PASS output to turn ON by the time set to timer. (Also delays
turning ON the HIGH and LOW outputs.)
Measured value
HIGH threshold
LOW threshold
HIGH output
ON
OFF
PASS output
ON
OFF
LOW output
ON
OFF
Time set to timer
Time set to timer