Design - Siemens SITRANS FC430 Operating Instructions Manual

Coriolis flowmeters with hart
Hide thumbs Also See for SITRANS FC430:
Table of Contents

Advertisement

Table 13- 24 ASME B16.5 [bar]
Class
150
300
600
900
Table 13- 25 DIN 11851 [bar]
PN (bar) / DN
25 / 50-100
40 / 10-40
13.9

Design

Sensor design
Table 13- 26 Sensor design
Description
Dimension and weight
Process connectors
FC430 with HART
Operating Instructions, 05/2015, A5E03361511-AF
-50
0
20.0
20..
51.7
51.7
103.4
103.4
155.1
155.1
-50
0
25
25
40
40
Temperature TS (°C)
50
100
19.5
17.7
51.7
51.5
103.4
103.0
153.0
145.0
Temperature TS (°C)
50
100
25
25
40
40
Specification
See "Dimensions and weight" (Page 223)
EN1092-1 B1, PN16, PN40, PN63, PN100,
PN160
EN1092-1 D (gasket groove), PN40, PN63,
PN100, PN160
ISO 228-1 G *
ASME B1.20.1 NPT *
ASME B16.5, Cl 150, Cl 300, Cl 600, Cl 900
DIN 11851 **
DIN 32676 *
DIN 11864-1A **, DIN 11864-2C (inch) **, DIN
11864-3A **
ISO 2852 **
ISO 2853 **
JIS B 2220, 10K, 20K, 40K, 62K
Technical data
13.9 Design
150
200
15.8
13.8
50.3
48.6
100.3
97.2
134.0
125.0
140
25
40
201

Advertisement