Description

3.1

Overview

The SITRANS F US ultrasonic flowmeter systems consist of a sensor and a transmitter. This
system consists of sensor type SONO 3100, SONO 3300 or SONOKIT and the transmitter type
FUS060. The following table shows the ultrasonic flowmeter systems with the transmitter type
FUS060:
Sensor type
SONO 3100
DN 100 – DN 1200
SONO 3300
DN 50 – DN 300
SONOKIT
DN 100 – DN 4000
These Operating Instructions is only for the transmitter part of the flowmeter system. The SONO
3100, SONO 3300 or SONOKIT sensors have separate operating instructions.
The FUS060 is configured in a combination of hardware (HW) and firmware (FW). For
communication via SIMATIC PDM firmware-specific device descriptions are needed. The various
relations are listed below:
Device
HW
02.00
02.00
02.00
04.00
3.2

Design

SITRANS FUS060 is an ultrasonic flow transmitter engineered for high performance and suitable
for use with 1-path, 2-path, and 4-path flow sensors.
The complete flowmeter consists of an ultrasonic flow sensor of the types SONO 3100, SONO
3300 or SONOKIT and the associated SITRANS FUS060 transmitter.
The ultrasonic flow sensors are available with diameters up to DN 4000.
SITRANS FUS060 with HART
Operating Instructions, 09/2021, A5E01204521-AL
Transmitter
Outputs
FUS060
1 analog with HART
1 frequency/pulse
1 relay
EDD (device description)
FW
1.00.01
2.01.04
X
2.01.07
X
3.00.00
4.00.00-15
Measurement
Volume flow rate
Total volume
Mass flow rate
Total mass
Sound velocity
Error indication
Limit monitoring
Ultrasonic amplitude
2.00.00
4.00.00
X
X
3