Default settings

The following tables show the default settings as well as the range for various parameters.
The parameters can be accessed on three levels.
● Read Only
Allows no configuration. The user is only able to view the parameter values. No PIN code
required.
● User
Allows configuration and service of all parameters except calibration parameters. Default
PIN code is 2457.
● Expert
Allows configuration and service of all parameters including flow and density calibration
parameters. Default PIN code is 2834.
C.1

Basic Settings

Table C- 1
Basic Settings
HMI menu ID
Parameter
2.1.1
Flow Direction
2.1.2
Process Noise Damping Select process noise damping
FC430 with HART
Operating Instructions, 05/2015, A5E03361511-AF
Description
Select pos/neg flow. Default
pos flow is indicated by arrow
on sensor.
level.
* 1: Low ... 5: High
Default value
Value range
[unit]
Positive
Negative
Positive
Duplex pump
Centrifugal
(3)
pump (1)
Triplex
pump (2)
Duplex
pump (3)
Simplex
pump (4)
Cam pump
(5)
C
Access
level
User
User