HMI menu ID
Parameter
2.4.6.7
Filter Time Constant
2.4.6.8
Fail Safe Mode
2.4.6.9
Fail Safe Value
2.4.6.10
Process Value
2.4.6.11
Direction
2.4.6.12
Frequency Value High
2.4.6.13
Frequency Value Low
2.4.6.14
Flow Value High
2)
2.4.6.15
Flow Value Low
2)
FC430 with HART
Operating Instructions, 05/2015, A5E03361511-AF
Description
Set filter time constant. Defines
the damping of the current
output signal.
Select current output reaction in
case of a fault.
Define fail-safe current output
value if "Fail Safe Mode" pa-
rameter is set to 'User Defined
Value'.
Select process value for fre-
quency output.
Select measured flow direction.
The flowmeter will only output
frequency when flow value is
measured in selected direction.
Assign maximum frequency
value.
Assign minimum frequency
value.
Assign process value to upper
output frequency "Frequency
Value Low".
Assign process value to upper
output frequency "Frequency
Value High".
Default value
Value range
[unit]
0.0
0.0 to 100.0
[s]
Minimum Cur-
Minimum
rent
Current
Maximum
Current
Last Good
Value
Current Value
User Defined
Value
0
0 to 25
[mA]
Massflow
Massflow
Volumeflow
Density
Fluid
Temperature
Corrected
Volumeflow
Fraction A
Fraction B
Fraction A %
Fraction B %
Bidirectional
Positive
Negative
Bidirectional
Bidirectional
(Symmetric)
1000.0
0.0 to 12500.0
[Hz]
0.0
0.0 to 12500.0
[Hz]
1)
1)
1)
1)
Default settings
C.4 Inputs/Outputs
Access
level
User
User
User
User
User
User
User
User
User
299