Connecting

5.9 Step 4a: Connecting the current output HART (channel 1)

6. Close and latch power supply terminal protection cover.
7. Tighten cable gland.
Missing PE/ground connection
Danger of electric shock. Ensure the PE/ground connection is secure before applying
power.
5.9
Step 4a: Connecting the current output HART (channel 1)
Note
4 to 20 mA output
It is not required to use shielded cables for the pure 4 to 20 mA current output.
Note
HART communication
It is recommended by the HART Communication Foundation (HCF) to use shielded cables
for the HART communication.
Passive channels only
Channel 1 power supply must be separated from that for channels 2 to 4.
Signal return (or common) can be joined.
1. Remove cap and ferrule from cable gland and slide onto cable.
2. Push cable through open gland and cable path.
3. Restore ferrule and tighten cap to lightly hold cable in place.
4. Signal cable screen is folded back over outer sheath and grounded beneath cable clamp.
68
WARNING
WARNING
Operating Instructions, 05/2015, A5E03361511-AF
FC430 with HART