Sample Services Configuration Script — Call Records Server (continued)
Do you wish to change any of the System parameters? [N] :
---------- Configuring additional parameters for UPS Monitoring -----------
An Uninterruptible Power Supply (UPS) can be used with VCX systems to avoid
disruption due to a power outage.
tracks the UPS's status and performs a safe shutdown when the its battery is
depleted during a long power outage.
compatible UPS installed and configured in accordance with the VCX documentation.
Enable UPS monitoring? [N]
Do you wish to change any of the UPS Monitoring parameters? [N] :
------------ Configuring additional parameters for Common Agent ------------
The Trap Destination specifies the IP address to be used as a destination
when this system sends SNMP traps.
Trap Destination
In some cases it may be desirable for SNMP Traps to be sent to multiple
destinations.
Additional Trap Destinations can be entered here.
input to indicate that all destinations have been entered.
IP Address of the first additional trap destination for this system.
Trap Destination
The Write Community String specifies the community string to be used by a
management station when sending write requests to this system.
Write Community String
The Read Community String specifies the community string to be used by a
management station when sending read requests to this system.
VCX provides a UPS monitoring service which
To use this feature, you must have a
Press the Enter or Return key to accept the default answer (N). If you
want to change any of the values, enter Y.
Enter the IP address of the PC or other system on which you are running
your network management software (for example, EMS).
CAUTION: Press the Enter or Return key to accept the default answer
(private). 3Com strongly recommends that users change this string for
security reasons.
:
:
Enter a blank
:
: private
249
Need help?
Do you have a question about the VCX V7000 and is the answer not in the manual?