Lenovo BladeCenter HX5 7873 Problem Determination And Service Manual page 209

Blade server
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See "Parts listing - BladeCenter HX5" on page 57 to determine which components are CRUs and which
components are FRUs.
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Type
Error Message
Information
Memory device X (DIMM X Status)
memory disabled [Note X = 1-16]
Information
Memory device X (MEU DIMM X
Status) memory disabled [Note X =
1-24]
Error Code: 0x806F0413
Note: Multiple events can be displayed for this error code. Be sure to read the message text to determine the
appropriate recovery actions.
Error
Expansion Module X, (BPE4_Y Slot Z)
PCI parity error
Notes:
1. X = Module number
2. Y = BPE4 ID (1, 2, 3, or 4). The
max BPE4 number is 4, and
there are 2 slots in each BPE4.
Module number is based on the
configuration of the BPE4
Error Code: 0x806F0507
Note: Multiple events can be displayed for this error code. Be sure to read the message text to determine the
appropriate recovery actions.
Action
1. Check the system event log for any memory errors that
might be related to the specified DIMM and resolve those
errors.
2. Enable the DIMM connector for the specified DIMM using
the Setup utility or the Advanced Settings Utility (ASU)
(see "Using the Setup utility" on page 20 or "Using the
Advanced Settings Utility (ASU)" on page 25).
3. Reseat the affected DIMM (see "Removing a DIMM -
BladeCenter HX5" on page 103 and "Installing a DIMM -
BladeCenter HX5" on page 104) and enable the DIMM
connector (see step 2).
4. Save the settings and exit from the Setup utility.
1. Check the system event log for any memory errors that
might be related to the specified DIMM and resolve those
errors.
2. Enable the DIMM connector for the specified DIMM using
the Setup utility or the Advanced Settings Utility (ASU)
(see "Using the Setup utility" on page 20 or "Using the
Advanced Settings Utility (ASU)" on page 25).
3. Reseat the affected DIMM (see "Removing a DIMM - IBM
MAX5 expansion blade" on page 107 and "Installing a
DIMM - IBM MAX5" on page 108) and enable the DIMM
connector (see step 2).
4. Save the settings and exit from the Setup utility.
1. If you have a PCI adapter in your blade server, verify that
the PCI adapter is supported in the blade server. For a list
of supported optional devices for the blade server, see
http://www.ibm.com/servers/eserver/serverproven/
compat/us/.
2. Reseat the PCI adapter (see "Removing an I/O expansion
card" on page 119 and "Installing an I/O expansion card"
on page 121).
.