Lenovo BladeCenter HX5 7873 Problem Determination And Service Manual page 220

Blade server
Table of Contents

Advertisement

Note: When you press the power button, the media tray select button/LED should also be lit if
the capacitor is charged. If the media tray select button/LED is lit but no LEDs on the system
board are lit, there are no hardware-related issues on the blade server. If the media tray select
LED fails to light, install the blade server in a chassis for approximately 2 hours to enable the
light path diagnostics panel to charge.
See "System-board LEDs - BladeCenter HX5" on page 15 for the location of the LEDs on the
system board. See "Light path diagnostics LEDs" on page 207 for information about resolving
those LEDs.
Step 4.
View the LEDs displayed on the access panel.
There are two types of access panels available with the BladeCenter HX5, depending on whether
the standard heat sinks or the tall heat sinks came installed with the blade server.
• If you have standard heat sinks, the following LED label is located on the access panel:
1
2
3
4
See Light
1
Path Below
System
2
Board
3
NMI
4
Mismatch
• If you have tall heat sinks, the following LEDs label is located on the left access panel:
See Light Path Below
This amber LED indicates that there is a problem with one of the servers in the scalable blade
complex, but the problem is not with this blade server. If this LED is lit, complete the following
steps:
1. Remove the blade server from the scalable blade complex (see "Disassembling a scalable
blade complex" on page 68 for instructions).
204
BladeCenter HX5 Blade ServerProblem Determination and Service Guide