3.
Install the drive by completing the following tasks.
a.
Slide the drive into the drive slot until it is fully seated.
b.
Close the latch to lock the drive in place.
4.
Return the drive to operation:
If you cold-serviced the drive, restore power to the server.
See
"Power On the Server" on page
If you hot-serviced the drive, configure it.
For example, type:
# cfgadm -c configure c0::dsk/c1t1d0
Replace c0:dsk/c1t1d0 with the drive name that applies to your situation.
If you hot-serviced an NVMe drive, it should automatically power up and
attach. If not, power up and attach the drive manually.
# hotplug enable /SYS/DBP/NVME0
Check that the drive's state has changed to enabled.
# hotplug list –lc
151.
Install a Drive
Servicing Drives