Oracle SPARC S7-2 Service Manual page 125

Hide thumbs Also See for SPARC S7-2:
Table of Contents

Advertisement

2.
Connect the cables to the drive backplane (1).
Connect the cable labeled "A" to the connector on the drive backplane
a.
labeled "NMVe A".
Connect the cable labeled "B" to the connector on the drive backplane
b.
labeled "NMVe B".
3.
Connect the NVMe card cables to the motherboard (2).
a.
Connect the cable labeled "2,3" to the connector on the motherboard labeled
"2,3".
This is the connector closer to the front of the server.
b.
Connect the cable labeled "0,1" to the connector on the motherboard labeled
"0,1".
This is the connector closer to the rear of the server.
4.
Install the server fan modules.
See
"Install a Fan Module" on page
5.
Install the server mid-wall (3).
a.
Position the mid-wall over the front of the motherboard so that it engages
the mushroom-shaped standoffs that are located on the server chassis
sidewall.
Ensure that SAS cables are not pinched by the mid-wall and that they run
b.
beside the mid-wall and not under it.
Tighten the four green captive screws to secure the mid-wall to the server
c.
chassis, use No. 2 Phillips screwdriver.
6.
Replace the air baffle.
Return the server to operation.
7.
See
"Returning the Server to Operation" on page
Related Information
"Remove the NVMe Cables" on page 122
65.
145.
Install the NVMe Cables
Servicing Cables
125